At MK Electric Man - Electrician, we provide premier residential and commercial electrical repair services in New Orleans, LA, as outlined in our Google My Business description: "Residential and Commercial Electrical Repair Service. Power and Lighting Installation. Troubleshooting Electricity Outages."

Recently, we completed an expert GFCI and receptacle installation for a homeowner in New Orleans, addressing multiple electrical issues including a faulty bathroom GFCI, a sparking receptacle near a computer, and three loose receptacles in the bedroom and living room.

This project required detailed troubleshooting and precise repairs to restore safety and functionality.

Below, we detail this job, showcasing our expertise, commitment to safety, and dedication to customer satisfaction in New Orleans, LA.

๐“๐ก๐ž ๐‚๐ก๐š๐ฅ๐ฅ๐ž๐ง๐ ๐ž: ๐Œ๐ฎ๐ฅ๐ญ๐ข๐ฉ๐ฅ๐ž ๐„๐ฅ๐ž๐œ๐ญ๐ซ๐ข๐œ๐š๐ฅ ๐ˆ๐ฌ๐ฌ๐ฎ๐ž๐ฌ ๐‚๐จ๐ฆ๐ฉ๐ซ๐จ๐ฆ๐ข๐ฌ๐ข๐ง๐  ๐’๐š๐Ÿ๐ž๐ญ๐ฒ

A homeowner in New Orleans contacted MK Electric Man to address several electrical problems in their home.

The bathroom GFCI outlet was not functioning, posing a safety risk in a wet environment where ground fault protection is critical.

A receptacle near the homeownerโ€™s computer was sparking, indicating a serious hazard that could lead to fire or equipment damage.

Additionally, three receptaclesโ€”one in the bedroom and two in the living roomโ€”were loose from the wall, creating unreliable connections and potential shock risks.

The client needed a skilled electrician in New Orleans, LA, to diagnose and repair these issues promptly to ensure their home was safe and operational.

Our team arrived quickly to troubleshoot, recognizing that each issue required careful analysis to identify the root causes and implement effective solutions.

The challenge was to address the faulty GFCI, sparking receptacle, and loose outlets while ensuring all repairs met National Electrical Code standards for safety.

Our goal was to restore reliable power, eliminate hazards, and provide the homeowner with peace of mind.

๐“๐ก๐ž ๐’๐จ๐ฅ๐ฎ๐ญ๐ข๐จ๐ง: ๐‚๐จ๐ฆ๐ฉ๐ซ๐ž๐ก๐ž๐ง๐ฌ๐ข๐ฏ๐ž ๐“๐ซ๐จ๐ฎ๐›๐ฅ๐ž๐ฌ๐ก๐จ๐จ๐ญ๐ข๐ง๐  ๐š๐ง๐ ๐‘๐ž๐ฉ๐ฅ๐š๐œ๐ž๐ฆ๐ž๐ง๐ญ๐ฌ

Our approach involved systematic troubleshooting of each electrical issue, followed by targeted repairs and installations.

We began with the bathroom GFCI, analyzing the outlet box, inspecting connections, and taking voltage readings.

The box was receiving the required 120 volts, but the GFCI device was faulty and needed replacement.

We removed the old GFCI, made new, secure connections, and installed a new 20-amp, 120-volt rated GFCI device with a cover plate, ensuring robust ground fault protection for the bathroom.

Testing confirmed the new GFCI functioned correctly, tripping as designed to prevent shocks in wet conditions.

Next, we addressed the sparking receptacle near the computer, a critical concern due to its fire hazard potential.

We analyzed the outlet box, inspected connections, and took voltage readings, finding that the Romex copper wiring with ground was in fair condition, with no signs of damage.

However, the receptacle itself was faulty, burning up internally due to wear or arcing.

We replaced the receptacle with a new 120-volt rated unit, making secure connections to the existing wiring to ensure reliable power delivery.

After installation, we tested the receptacle, confirming it operated safely with no sparking, protecting the computer and surrounding area.

Finally, we tackled the three loose receptacles in the bedroom and living room, which were unreliable and posed shock risks due to poor wall mounting.

We inspected each receptacle, tightening and securing them to their respective outlet boxes to ensure firm connections.

No wiring or device replacements were needed, as the receptacles themselves were functional once properly mounted.

We tested all three receptacles, verifying they delivered consistent power without movement or instability.

A final inspection ensured all repairsโ€”GFCI replacement, receptacle replacement, and securing loose outletsโ€”met local electrical codes and provided a safe, reliable electrical system.

The homeownerโ€™s bathroom, computer area, bedroom, and living room were fully operational, with all hazards eliminated.

๐Œ๐š๐ญ๐ž๐ซ๐ข๐š๐ฅ๐ฌ ๐”๐ฌ๐ž๐

For this project, we used high-quality, code-compliant materials to ensure a safe and durable solution, including a 20-amp, 120-volt rated GFCI device with cover plate for bathroom safety, a 120-volt rated receptacle to replace the sparking unit near the computer, and no additional materials for the loose receptacles, which required only tightening and securing.

๐๐ซ๐จ๐ฃ๐ž๐œ๐ญ ๐๐ฎ๐๐ ๐ž๐ญ

The cost for this expert GFCI and receptacle installation varies based on the scope, so we encourage homeowners to call MK Electric Man for a personalized quote.

Our pricing is transparent and competitive, typically ranging from $195-$375 for similar multi-issue repairs, covering labor, materials, and our commitment to quality service.

We provide affordable solutions that deliver lasting value and safety to homes in New Orleans, LA.

๐–๐ก๐ฒ ๐‚๐ก๐จ๐จ๐ฌ๐ž ๐Œ๐Š ๐„๐ฅ๐ž๐œ๐ญ๐ซ๐ข๐œ ๐Œ๐š๐ง ๐Ÿ๐จ๐ซ ๐„๐ฅ๐ž๐œ๐ญ๐ซ๐ข๐œ๐š๐ฅ ๐‘๐ž๐ฉ๐š๐ข๐ซ๐ฌ

This project underscores MK Electric Manโ€™s expertise in troubleshooting and resolving multiple electrical issues with precision and care.

Homeowners and businesses in New Orleans, LA, trust us for our rapid response, as our skilled technicians quickly diagnose problems like faulty GFCIs, sparking receptacles, and loose outlets.

We prioritize safety, adhering to National Electrical Code standards to deliver reliable, hazard-free systems.

Our team is adept at handling diverse electrical repairs, ensuring comprehensive solutions tailored to each clientโ€™s needs.

We offer affordable, transparent pricing, delivering high-quality repairs without unexpected costs.

The homeowner was thrilled with the restored functionality and enhanced safety, reflecting our dedication to exceeding expectations.

๐‚๐จ๐ฆ๐ฆ๐จ๐ง ๐„๐ฅ๐ž๐œ๐ญ๐ซ๐ข๐œ๐š๐ฅ ๐ˆ๐ฌ๐ฌ๐ฎ๐ž๐ฌ ๐ข๐ง ๐‡๐จ๐ฆ๐ž๐ฌ

The issues in this New Orleans home are common, often including faulty GFCI devices failing to provide ground fault protection, sparking receptacles due to internal wear or arcing, loose receptacles causing unreliable connections or shock risks, or overloaded circuits leading to device failures.

If youโ€™re experiencing these or similar issues, MK Electric Man is equipped to provide expert solutions tailored to your needs.

๐‚๐จ๐ง๐ญ๐š๐œ๐ญ ๐Œ๐Š ๐„๐ฅ๐ž๐œ๐ญ๐ซ๐ข๐œ ๐Œ๐š๐ง ๐“๐จ๐๐š๐ฒ

For GFCI and receptacle installations, electrical repairs, or power and lighting solutions, MK Electric Man - Electrician is your trusted partner in New Orleans, LA.

Whether youโ€™re dealing with sparking outlets, faulty GFCIs, or loose receptacles, our team delivers fast, safe, and affordable solutions.

๐‚๐š๐ฅ๐ฅ ๐ฎ๐ฌ ๐ญ๐จ๐๐š๐ฒ ๐ญ๐จ ๐ฌ๐œ๐ก๐ž๐๐ฎ๐ฅ๐ž ๐š๐ง ๐š๐ฉ๐ฉ๐จ๐ข๐ง๐ญ๐ฆ๐ž๐ง๐ญ ๐จ๐ซ ๐ซ๐ž๐ช๐ฎ๐ž๐ฌ๐ญ ๐š ๐ช๐ฎ๐จ๐ญ๐ž.

Let MK Electric Man power your home or business with expert electrical services designed to meet your needs.

Service provided: GFCI Outlet Repair

Location: New Orleans, LA

Project Image Gallery

Contact MK Electric Man